Bug Description
The current implementation consider a given value of DGT for evaluating the Gain/Tilt profile along frequency, which provides roughly 1dB Tilt mismatch between expected and evaluated values.
To Reproduce the Bug
Steps to reproduce the behavior:
- Consider one EDFA
- Evaluate the DGT measuring two gain profiles with distinct values of target tilt and a fixed value of target gain (see R. D. Muro, “The er3+-fiber gain coefficient derived from a dynamic gain tilt technique”, JLT, vol. 18, no. 3, pp. 343–347, 2000. DOI: 10.
1109/50.827506) - Set the measured DGT in the EDFA input
- Compare the GNPy evaluated and the measured gain profiles
Proposed Solution
An advanced implementation of EDFA gain profile evaluation is shown in the figure.