Description
I keep observing that after a automatic successfull Solar²DHW Operation the Operation mode switch changes to cool or heat only by "magic" and begin to work in this mode.
08/07 15:41:19 - MQTT Command: SetZ1HeatRequestTemperature: 0 (SoftStart)
08/07 15:41:19 - Functions Final setpoint: Current temperature shift: -1 °C. Calculated new temperature shift: 0 °C
08/07 15:40:39 - Function SoftStart: Correction: -1 > 0 °C - (ENDING) Freq: 21Hz
08/07 15:25:39 - Functions Final setpoint: Current temperature shift: -2 °C. Calculated new temperature shift: -1 °C
08/07 15:25:39 - Function SoftStart: Correction: -2 > -1 °C - (ENDING) Freq: 21Hz
08/07 15:19:59 - SYSTEM - HEISHAMON Connection: Online
08/07 15:19:45 - SYSTEM - HEISHAMON Connection: Offline
08/07 15:10:39 - Functions Final setpoint: Current temperature shift: -3 °C. Calculated new temperature shift: -2 °C
08/07 15:10:39 - Function SoftStart: Correction: -3 > -2 °C - (ENDING) Freq: 20Hz
08/07 14:55:38 - Functions Final setpoint: Current temperature shift: -4 °C. Calculated new temperature shift: -3 °C
08/07 14:55:38 - Function SoftStart: Correction: -4 > -3 °C - (ENDING) Freq: 19Hz
08/07 14:49:18 - SYSTEM - HEISHAMON Connection: Online
08/07 14:49:08 - SYSTEM - HEISHAMON Connection: Offline
08/07 14:40:38 - Functions Final setpoint: Current temperature shift: -5 °C. Calculated new temperature shift: -4 °C
08/07 14:40:38 - Function SoftStart: Correction: -5 > -4 °C - (ENDING) Freq: 19Hz
08/07 14:29:49 - Function SoftStart: Correction: -17 > -5 °C - (STABLE) Freq: 19Hz
08/07 14:28:49 - Function SoftStart: --> Pump relaxed... (19Hz) Continuing with Phase 2
08/07 14:28:39 - Function SoftStart: Correction: -17 > -17 °C - (EVALUATING) Freq: 19Hz
08/07 14:28:38 - Functions Final setpoint: Current temperature shift: -5 °C. Calculated new temperature shift: -5 °C
08/07 14:28:38 - Function SoftStart: Correction: -5 > -17 °C - (EVALUATING) Freq: 19Hz
08/07 14:25:38 - Compressor: running
08/07 14:25:38 - Functions Final setpoint: Current temperature shift: 0 °C. Calculated new temperature shift: -5 °C
08/07 14:25:38 - Function Pump speed: Max pumpspeed set to 254 (100%) (HEAT)
08/07 14:25:38 - Function SoftStart: Correction: 0 > -5 °C - (STARTUP) Freq: 19Hz
08/07 14:22:39 - TOP4_Operating_Mode_State: 0
08/07 14:22:36 - Function Solar²DHW: Cooldown period (15 minutes) has ended. Solar function done for today
08/07 14:22:20 - MQTT Command: SetOperationMode: 0
08/07 14:22:19 - MQTT Command: SetDHWTemp: 40 (Solar)
08/07 14:22:18 - Function Solar²DHW: Restoring DHW setpoint to: 40°C
08/07 14:22:18 - Function Solar²DHW: Stored next operating mode is removed
08/07 14:22:18 - Function Solar²DHW: Restoring previous OperatingMode: 0
08/07 14:22:18 - Function Solar²DHW: Cooldown period (15 minutes) has ended. Solar function done for today
08/07 14:10:38 - Compressor: stopped
08/07 14:10:38 - TOP20_ThreeWay_Valve_State: 0
08/07 14:07:18 - Function Solar²DHW: DHW temperature has reached SP high
08/07 12:47:36 - Compressor: running
08/07 12:44:36 - TOP20_ThreeWay_Valve_State: 1
08/07 12:44:36 - TOP4_Operating_Mode_State: 3
08/07 12:44:23 - MQTT Command: SetOperationMode: 3
08/07 12:44:22 - MQTT Command: SetDHWTemp: 60 (Solar)
08/07 12:44:21 - MQTT Command: SetHeatpump: 1 (Solar)
08/07 12:44:21 - Function Solar²DHW: Operation mode changed from 0 to 3
08/07 12:44:21 - Function Solar²DHW: triggered threshold (kW). DHW SP to 60
08/07 12:44:21 - Function Solar²DHW: Stored next operating mode is set to 0
Am I making a mistake somewhere?
Kind reagards,
Martin