@@ -5,14 +5,16 @@ r,,State,,,,,07,energy,,UCH,,,,,,energy,,,,,,onoff,,,,state,,UCH,0x01=ready;0x0b
55*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,,
66r,,EnergyHc,,,,,00,,,energy,,,,,,,,,,,,,,,,,,,,,
77r,,EnergyCool,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,
8- r,,Hours,,,,,40,,,energy,,,,,,,,,,,,,,,,,,,,,
9- r,,HoursHc,,,,,41,,,energy,,,,,,,,,,,,,,,,,,,,,
10- r,,HoursCool,,,,,43,,,energy,,,,,,,,,,,,,,,,,,,,,
8+ r,,EnergyYieldHwc,energy yield hot water,,,,16,,,energy4,,,,,,,,,,,,,,,,,,,,,
9+ r,,Hours,operation hours,,,,40,,,hoursum,,,,,,,,,,,,,,,,,,,,,
10+ r,,HoursHc,operation hours heating,,,,41,,,hoursum,,,,,,,,,,,,,,,,,,,,,
11+ r,,HoursCool,operation hours cooling,,,,43,,,hoursum,,,,,,,,,,,,,,,,,,,,,
1112# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
12- r,,EnergyIntegral,,,,,21,,,integral,,°min,current energy integral in °min,,,,,,,,,,,,,,,,,,
13- r,,CurrentYieldPower,,,,,23,,,D1B,10,kW,current yielded energy from the environment in kW,,,,,,,,,,,,,,,,,,
14- r,,CurrentConsumedPower,,,,,24,,,D1B,10,kW,current power consumption of the heatpump in kW,,,,,,,,,,,,,,,,,,
15- r,,CurrentCompressorUtil,,,,,25,,,D1B,,%,current compressor utilization in percent,,,,,,,,,,,,,,,,,,
13+ r,,EnergyIntegral,current energy integral,,,,21,,,integral,,,,,,,,,,,,,,,,,,,,,
14+ r,,CurrentYieldPower,current yielded energy from the environment,,,,23,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
15+ r,,CurrentConsumedPower,current power consumption,,,,24,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
16+ r,,CurrentCompressorUtil,current compressor utilization,,,,25,,,D1B,,%,,,,,,,,,,,,,,,,,,,
17+ r,,AirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
1618# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
1719*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,,
1820r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,
@@ -50,16 +52,51 @@ r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
5052# Test menus on VWZ. EnableTest message needs to be sent before each of the read messages work.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
5153*rs,#service,,,,,"B514",05,,,IGN:2,,,,,,,,,,,,,,,,,,,,,
5254*ws,#service,,,,,"B514",05,ignore,,HEX:3,="03FFFF",,,,,,,,,,,,,,,,,,,,
53- ws,,EnableTestEEVPosition,Read T.008,,,,15
54- rs,,TestEEVPosition,T.008 value,,,,15,,,UIN,,,
55- ws,,EnableTestCompressorExitTemp,Read T.026,,,,37
56- rs,,TestCompressorExitTemp,T.026 value,,,,37,,,SIN,10,°C,,
57- ws,,EnableTestCompressorIntakeTemp,Read T.027,,,,38
58- rs,,TestCompressorIntakeTemp,T.027 value,,,,38,,,SIN,10,°C,,
59- ws,,EnableTestWaterThroughput,Read T.016,,,,2B
60- rs,,TestWaterThroughput,current heating water flow rate,,,,2B,,,UIN,,l/h,
61- ws,,EnableTestCompressorSpeed,Read T.068,,,,5D
62- rs,,TestCompressorSpeed,T.068 value,,,,5D,,,UIN,10,,
55+ ws,,EnableTestEEVPosition,Read EEV position,,,,15
56+ rs,,TestEEVPosition,EEV position,,,,15,,,percent0,,,T.0.21
57+ ws,,EnableTestCompressorExitTemp,Read compressor outlet temperature,,,,37
58+ rs,,TestCompressorExitTemp,compressor outlet temperature,,,,37,,,SIN,10,°C,T.0.55
59+ ws,,EnableTestCompressorIntakeTemp,Read compressor inlet temperature,,,,38
60+ rs,,TestCompressorInletTemp,compressor inlet temperature,,,,38,,,SIN,10,°C,T.0.56
61+ ws,,EnableTestWaterThroughput,Read current heating water flow rate,,,,2B
62+ rs,,TestWaterThroughput,current heating water flow rate,,,,2B,,,UIN,,l/h,T.0.45
63+ ws,,EnableTestCompressorSpeed,Read compressor speed,,,,5D
64+ rs,,TestCompressorSpeed,compressor speed,,,,5d,,,SIN,10,U/s,T.0.93
65+ # installer level test menu sensor/actor test from PR #174
66+ rs,,TestBuildingPumpPower,building pump power,,,,01,,,percent0,,,T.0.01
67+ rs,,TestFan1,fan 1,,,,11,,,percent0,,,T.0.02
68+ rs,,TestCondensateTrayHeater,condensate tray heater,,,,13,,,onoff,,,T.0.19
69+ rs,,TestFourWayValve,4 way valve,,,,14,,,onoff,,,T.0.20
70+ rs,,TestHeatingCoilCompressor,heating coil compressor,,,,17,,,onoff,,,T.0.23
71+ rs,,TestFlowTemp,flow temperature,,,,28,,,SIN,10,°C,T.0.40
72+ rs,,TestReturnTemp,return temperature,,,,29,,,SIN,10,°C,T.0.41
73+ rs,,TestBuildingWaterPress,building water pressure,,,,2a,,,UIN,10,bar,T.0.42
74+ rs,,TestAirIntakeTemp,air intake temperature,,,,30,,,SIN,10,°C,T.0.48
75+ rs,,TestEEVOutletTemp,EEV outlet temperature,,,,39,,,SIN,10,°C,T.0.57
76+ rs,,TestCondensorOutletTemp,condensor outlet temperature,,,,3b,,,SIN,10,°C,T.0.59
77+ rs,,TestHighPress,high pressure,,,,3f,,,SIN,10,bar,T.0.63
78+ rs,,TestLowPress,low pressure,,,,40,,,SIN,10,bar,T.0.64
79+ rs,,TestHighPressureSwitch,high pressure switch,,,,43,,,UIN,0=open;1=close,,T.0.67
80+ rs,,TestEvaporationTemp,evaporation temperature,,,,55,,,SIN,10,°C,T.0.85
81+ rs,,TestCondensateTemp,condensate temperature,,,,56,,,SIN,10,°C,T.0.86
82+ rs,,TestOverheatingTargetValue,overheating target value,,,,57,,,SIN,10,K,T.0.87
83+ rs,,TestOverheatingActualValue,overheating current value,,,,58,,,SIN,10,K,T.0.88
84+ rs,,TestSubcoolingTargetValue,sub cooling target value,,,,59,,,SIN,10,K,T.0.89
85+ rs,,TestSubcoolingActualValue,sub cooling current value,,,,5a,,,SIN,10,K,T.0.90
86+ rs,,TestTempSwitchCompressorOutlet,temperature switch compressor outlet,,,,7b,,,UIN,0=open;1=close,,T.0.123
87+ rs,,TestPrioritySwitchingValve,priority switch valve WW,,,,02,,,switchvalve,,,T.1.02
88+ rs,,TestCylinderTemp,storage temperature,,,,2c,,,SIN,10,°C,T.1.44
89+ rs,,TestLockoutContactS20,lockout contact S20,,,,2e,,,UIN,0=close;1=open,,T.1.46
90+ rs,,TestOutdoorTemp,outside temperature,,,,45,,,SIN,10,°C,T.1.69
91+ rs,,TestSystemTemp,system temperature,,,,46,,,SIN,10,°C,T.1.70
92+ rs,,TestDCFStatus,DCF status,,,,47,,,UIN,,,T.1.71
93+ rs,,TestLockoutContactS21,lockout contact S21,,,,48,,,UIN,0=close;1=open,,T.1.72
94+ rs,,TestMA1Output,MA1 output,,,,77,,,onoff,,,T.1.119
95+ rs,,TestImmersionHeaterSafetyCutOut,STB heater,,,,7c,,,UIN,0=close;1=open,,T.1.124
96+ rs,,TestMIInput,ME input,,,,7d,,,SIN,,,T.1.125
97+ rs,,TestMO2Output,MA2 output,,,,7e,,,onoff,,,T.1.126
98+ rs,,TestMO3Output,MA3 output,,,,7f,,,onoff,,,T.1.127
99+ rs,,TestFlowTempImmersionHeater,Vorlauftemperatur Heizstab,,,,82,,,SIN,10,°C,T1.130
63100# Values from Live Monitor. EnableLiveMonitor message needs to be sent before each of the read messages work.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
64101*us,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
65102*ws,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
@@ -79,5 +116,16 @@ rs,,LiveMonitorCurrentConsumedPower,current power consumption,,,,24,,,UIN,10,kW,
79116rs,,LiveMonitorCurrentCompressorUtil,compressor modulation,,,,25,,,D1B,,%,,,,,,,,,,,,,
80117# example: 3108b51a0405003226 / 0a000808df000000000000
81118rs,,LiveMonitorAirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
119+ # installer level test menu statistics from PR #174
120+ *ri,#install,,,,,"B51A","05",,,IGN:3,,,,
121+ ri,,CompressorHours,compressor hours,,,,b43400,,,hoursum,,,
122+ ri,,CompressorStarts,compressor starts,,,,b43401,,,UIN,,,
123+ ri,,BuildingPumpHours,building punp hours,,,,b43402,,,hoursum,,,
124+ ri,,BuildingPumpStarts,building punp starts,,,,b43403,,,UIN,,,
125+ ri,,FourWayValveHours,4 way valve hours,,,,073406,,,hoursum,,,
126+ ri,,FourWayValveSwitchingOperations,4 way valve switching operations,,,,363407,,,UIN,,,
127+ ri,,Fan1Hours,fan 1 hours,,,,3c3451,,,hoursum,,,
128+ ri,,Fan1Starts,fan 1 starts,,,,d63452,,,UIN,,,
129+ ri,,EEVSteps,EEV steps,,,,e4340d,,,UIN,,,
82130!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
83131!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,