csvall.sh

Lines changed: 2 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -30,6 +30,8 @@ sed -i \
3030
-e 's#,UCH,,,"Off=0, On=1"#,onoff,,,#' \
3131
-e 's#,UCH,240=no;15=yes,#,yesno2,,#' \
3232
-e 's#,RückmeldungB#,RueckmeldungB#' \
33+
-e 's#ReglerCurrentTEMP#ReglerCurrentTemp#' \
34+
-e 's#\(,CounterStartattempts[.*],\)temp0,#\1UCH,#' \
3335
\{\} \; \
3436
&& npm run csv2tsp \
3537
&& npm run csv2tsp-combine \

ebusd-2.1.x/en/vaillant/08.hmu.csv

Lines changed: 65 additions & 17 deletions
Original file line numberDiff line numberDiff line change
@@ -5,14 +5,16 @@ r,,State,,,,,07,energy,,UCH,,,,,,energy,,,,,,onoff,,,,state,,UCH,0x01=ready;0x0b
55
*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,,
66
r,,EnergyHc,,,,,00,,,energy,,,,,,,,,,,,,,,,,,,,,
77
r,,EnergyCool,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,
8-
r,,Hours,,,,,40,,,energy,,,,,,,,,,,,,,,,,,,,,
9-
r,,HoursHc,,,,,41,,,energy,,,,,,,,,,,,,,,,,,,,,
10-
r,,HoursCool,,,,,43,,,energy,,,,,,,,,,,,,,,,,,,,,
8+
r,,EnergyYieldHwc,energy yield hot water,,,,16,,,energy4,,,,,,,,,,,,,,,,,,,,,
9+
r,,Hours,operation hours,,,,40,,,hoursum,,,,,,,,,,,,,,,,,,,,,
10+
r,,HoursHc,operation hours heating,,,,41,,,hoursum,,,,,,,,,,,,,,,,,,,,,
11+
r,,HoursCool,operation hours cooling,,,,43,,,hoursum,,,,,,,,,,,,,,,,,,,,,
1112
# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
12-
r,,EnergyIntegral,,,,,21,,,integral,,°min,current energy integral in °min,,,,,,,,,,,,,,,,,,
13-
r,,CurrentYieldPower,,,,,23,,,D1B,10,kW,current yielded energy from the environment in kW,,,,,,,,,,,,,,,,,,
14-
r,,CurrentConsumedPower,,,,,24,,,D1B,10,kW,current power consumption of the heatpump in kW,,,,,,,,,,,,,,,,,,
15-
r,,CurrentCompressorUtil,,,,,25,,,D1B,,%,current compressor utilization in percent,,,,,,,,,,,,,,,,,,
13+
r,,EnergyIntegral,current energy integral,,,,21,,,integral,,,,,,,,,,,,,,,,,,,,,
14+
r,,CurrentYieldPower,current yielded energy from the environment,,,,23,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
15+
r,,CurrentConsumedPower,current power consumption,,,,24,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
16+
r,,CurrentCompressorUtil,current compressor utilization,,,,25,,,D1B,,%,,,,,,,,,,,,,,,,,,,
17+
r,,AirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
1618
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
1719
*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,,
1820
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,
@@ -50,16 +52,51 @@ r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
5052
# Test menus on VWZ. EnableTest message needs to be sent before each of the read messages work.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
5153
*rs,#service,,,,,"B514",05,,,IGN:2,,,,,,,,,,,,,,,,,,,,,
5254
*ws,#service,,,,,"B514",05,ignore,,HEX:3,="03FFFF",,,,,,,,,,,,,,,,,,,,
53-
ws,,EnableTestEEVPosition,Read T.008,,,,15
54-
rs,,TestEEVPosition,T.008 value,,,,15,,,UIN,,,
55-
ws,,EnableTestCompressorExitTemp,Read T.026,,,,37
56-
rs,,TestCompressorExitTemp,T.026 value,,,,37,,,SIN,10,°C,,
57-
ws,,EnableTestCompressorIntakeTemp,Read T.027,,,,38
58-
rs,,TestCompressorIntakeTemp,T.027 value,,,,38,,,SIN,10,°C,,
59-
ws,,EnableTestWaterThroughput,Read T.016,,,,2B
60-
rs,,TestWaterThroughput,current heating water flow rate,,,,2B,,,UIN,,l/h,
61-
ws,,EnableTestCompressorSpeed,Read T.068,,,,5D
62-
rs,,TestCompressorSpeed,T.068 value,,,,5D,,,UIN,10,,
55+
ws,,EnableTestEEVPosition,Read EEV position,,,,15
56+
rs,,TestEEVPosition,EEV position,,,,15,,,percent0,,,T.0.21
57+
ws,,EnableTestCompressorExitTemp,Read compressor outlet temperature,,,,37
58+
rs,,TestCompressorExitTemp,compressor outlet temperature,,,,37,,,SIN,10,°C,T.0.55
59+
ws,,EnableTestCompressorIntakeTemp,Read compressor inlet temperature,,,,38
60+
rs,,TestCompressorInletTemp,compressor inlet temperature,,,,38,,,SIN,10,°C,T.0.56
61+
ws,,EnableTestWaterThroughput,Read current heating water flow rate,,,,2B
62+
rs,,TestWaterThroughput,current heating water flow rate,,,,2B,,,UIN,,l/h,T.0.45
63+
ws,,EnableTestCompressorSpeed,Read compressor speed,,,,5D
64+
rs,,TestCompressorSpeed,compressor speed,,,,5d,,,SIN,10,U/s,T.0.93
65+
# installer level test menu sensor/actor test from PR #174
66+
rs,,TestBuildingPumpPower,building pump power,,,,01,,,percent0,,,T.0.01
67+
rs,,TestFan1,fan 1,,,,11,,,percent0,,,T.0.02
68+
rs,,TestCondensateTrayHeater,condensate tray heater,,,,13,,,onoff,,,T.0.19
69+
rs,,TestFourWayValve,4 way valve,,,,14,,,onoff,,,T.0.20
70+
rs,,TestHeatingCoilCompressor,heating coil compressor,,,,17,,,onoff,,,T.0.23
71+
rs,,TestFlowTemp,flow temperature,,,,28,,,SIN,10,°C,T.0.40
72+
rs,,TestReturnTemp,return temperature,,,,29,,,SIN,10,°C,T.0.41
73+
rs,,TestBuildingWaterPress,building water pressure,,,,2a,,,UIN,10,bar,T.0.42
74+
rs,,TestAirIntakeTemp,air intake temperature,,,,30,,,SIN,10,°C,T.0.48
75+
rs,,TestEEVOutletTemp,EEV outlet temperature,,,,39,,,SIN,10,°C,T.0.57
76+
rs,,TestCondensorOutletTemp,condensor outlet temperature,,,,3b,,,SIN,10,°C,T.0.59
77+
rs,,TestHighPress,high pressure,,,,3f,,,SIN,10,bar,T.0.63
78+
rs,,TestLowPress,low pressure,,,,40,,,SIN,10,bar,T.0.64
79+
rs,,TestHighPressureSwitch,high pressure switch,,,,43,,,UIN,0=open;1=close,,T.0.67
80+
rs,,TestEvaporationTemp,evaporation temperature,,,,55,,,SIN,10,°C,T.0.85
81+
rs,,TestCondensateTemp,condensate temperature,,,,56,,,SIN,10,°C,T.0.86
82+
rs,,TestOverheatingTargetValue,overheating target value,,,,57,,,SIN,10,K,T.0.87
83+
rs,,TestOverheatingActualValue,overheating current value,,,,58,,,SIN,10,K,T.0.88
84+
rs,,TestSubcoolingTargetValue,sub cooling target value,,,,59,,,SIN,10,K,T.0.89
85+
rs,,TestSubcoolingActualValue,sub cooling current value,,,,5a,,,SIN,10,K,T.0.90
86+
rs,,TestTempSwitchCompressorOutlet,temperature switch compressor outlet,,,,7b,,,UIN,0=open;1=close,,T.0.123
87+
rs,,TestPrioritySwitchingValve,priority switch valve WW,,,,02,,,switchvalve,,,T.1.02
88+
rs,,TestCylinderTemp,storage temperature,,,,2c,,,SIN,10,°C,T.1.44
89+
rs,,TestLockoutContactS20,lockout contact S20,,,,2e,,,UIN,0=close;1=open,,T.1.46
90+
rs,,TestOutdoorTemp,outside temperature,,,,45,,,SIN,10,°C,T.1.69
91+
rs,,TestSystemTemp,system temperature,,,,46,,,SIN,10,°C,T.1.70
92+
rs,,TestDCFStatus,DCF status,,,,47,,,UIN,,,T.1.71
93+
rs,,TestLockoutContactS21,lockout contact S21,,,,48,,,UIN,0=close;1=open,,T.1.72
94+
rs,,TestMA1Output,MA1 output,,,,77,,,onoff,,,T.1.119
95+
rs,,TestImmersionHeaterSafetyCutOut,STB heater,,,,7c,,,UIN,0=close;1=open,,T.1.124
96+
rs,,TestMIInput,ME input,,,,7d,,,SIN,,,T.1.125
97+
rs,,TestMO2Output,MA2 output,,,,7e,,,onoff,,,T.1.126
98+
rs,,TestMO3Output,MA3 output,,,,7f,,,onoff,,,T.1.127
99+
rs,,TestFlowTempImmersionHeater,Vorlauftemperatur Heizstab,,,,82,,,SIN,10,°C,T1.130
63100
# Values from Live Monitor. EnableLiveMonitor message needs to be sent before each of the read messages work.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
64101
*us,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
65102
*ws,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
@@ -79,5 +116,16 @@ rs,,LiveMonitorCurrentConsumedPower,current power consumption,,,,24,,,UIN,10,kW,
79116
rs,,LiveMonitorCurrentCompressorUtil,compressor modulation,,,,25,,,D1B,,%,,,,,,,,,,,,,
80117
# example: 3108b51a0405003226 / 0a000808df000000000000
81118
rs,,LiveMonitorAirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
119+
# installer level test menu statistics from PR #174
120+
*ri,#install,,,,,"B51A","05",,,IGN:3,,,,
121+
ri,,CompressorHours,compressor hours,,,,b43400,,,hoursum,,,
122+
ri,,CompressorStarts,compressor starts,,,,b43401,,,UIN,,,
123+
ri,,BuildingPumpHours,building punp hours,,,,b43402,,,hoursum,,,
124+
ri,,BuildingPumpStarts,building punp starts,,,,b43403,,,UIN,,,
125+
ri,,FourWayValveHours,4 way valve hours,,,,073406,,,hoursum,,,
126+
ri,,FourWayValveSwitchingOperations,4 way valve switching operations,,,,363407,,,UIN,,,
127+
ri,,Fan1Hours,fan 1 hours,,,,3c3451,,,hoursum,,,
128+
ri,,Fan1Starts,fan 1 starts,,,,d63452,,,UIN,,,
129+
ri,,EEVSteps,EEV steps,,,,e4340d,,,UIN,,,
82130
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
83131
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,