Describe the bug
The time conversion is done from datetime when querying for technical indicators is to a nanoseconds resolution which conflicts with what Polygon is expecting (milliseconds). This, in turn, leads to Polygon thinking the wrong period is queried.

Code Links

As you can see, this is different from the way say the Aggregates call is done:
https://github.com/polygon-io/client-python/blob/b47b85245c24dcfd116ee93338ceba0c5f341f77/polygon/rest/aggs.py#L41-L45

The aggregates call is the right way. The SMA indicator also expects a millisecond timestamp: https://polygon.io/docs/stocks/get_v1_indicators_sma__stockticker