GivTCP Battery Card by @Codegnosis
home-assistant battery card for GivTCP users. Displays some basic stats in a single card:
- SOC %
- SOC Wh/kWh
- Status (Charge/Discharge/Idle)
- Current usage (in/out)
- Status context countdown/Time left until full charge or discharge (to reserve)
- Status context estimated date/time of full charge or discharge (to reserve)
You need to have GivTCP integrated into your home-assistant (either as an addon or a standalone docker container).
givtcp-battery-card is now included in the HACS Default repository
- install HACS you need to install this first.
- inside home-assistant go to HACS -> Frontend and click "Explore & Download Repositories"
- Search for "givtcp-battery-card" & install using the UI
Alternatively, manually install by adding it as a custom repository.
- install HACS you need to install this first.
- inside home-assistant go to HACS -> Frontend then click the 3 dots in the upper right hand corner.
- select Custom repositories from the menu and enter https://github.com/Codegnosis/givtcp-battery-card in the Repository box and select Lovelace for the Category.
- install the
givtcp-battery-cardusing the UI
Edit your chosen dashboard and use the "Add Card" button to select the "GivTCP Battery Card" from the list.
| Name | Type | Requirement | Description | Default |
|---|---|---|---|---|
type |
string | Required | custom:givtcp-battery-card |
|
entity |
string | Required | Home Assistant entity ID. | none |
name |
string | Optional | Card name | Battery |
soc_threshold_very_high |
number | Optional | When SOC is >= this, soc_threshold_very_high_colour is used for the icon colour |
80 |
soc_threshold_high |
number | Optional | When SOC is >= this, soc_threshold_high_colour is used for the icon colour |
60 |
soc_threshold_medium |
number | Optional | When SOC is >= this, soc_threshold_medium_colour is used for the icon colour |
40 |
soc_threshold_low |
number | Optional | When SOC is >= this, soc_threshold_low_colour is used for the icon colour |
20 |
soc_colour_input |
string | Optional | Input type for the colours. One of rgb_picker or theme_var |
rgb_picker |
soc_threshold_very_high_colour |
array/string | Optional | RGB value or theme variable name (e.g. --success-color) for icon colour when SOC >= soc_threshold_very_high |
[0, 69, 23] |
soc_threshold_high_colour |
array/string | Optional | RGB value or theme variable name (e.g. --success-color) for icon colour when SOC >= soc_threshold_high |
[67, 160, 71] |
soc_threshold_medium_colour |
array/string | Optional | RGB value or theme variable name (e.g. --success-color) for icon colour when SOC >= soc_threshold_medium |
[255, 166, 0] |
soc_threshold_low_colour |
array/string | Optional | RGB value or theme variable name (e.g. --success-color) for icon colour when SOC >= soc_threshold_low |
[219, 68, 55] |
soc_threshold_very_low_colour |
array/string | Optional | RGB value or theme variable name (e.g. --success-color) for icon colour when SOC < soc_threshold_low |
[94, 0, 0] |
display_abs_power |
boolean | Optional | Display the battery power usage as an absolute (unsigned integer) value | false |
display_type |
number | Optional | Display type. 0: Wh, 1: kWh, 2: Dynamic | 3 |
display_dp |
number | Optional | Round to decimal places for display_type kWh or Dynamic. 1 - 3 |
3 |
icon_status_idle |
string | Optional | Icon for Idle battery status | mdi:sleep |
icon_status_charging |
string | Optional | Icon for Charging battery status | mdi:lightning-bolt |
icon_status_discharging |
string | Optional | Icon for Discharging battery status | mdi:home-battery |
display_battery_rates |
boolean | Optional | Display charge/dischare rate as % and graphical bar | true |
use_custom_dod |
boolean | Optional | Use custom DoD % to override GivTCP capacity & SoC values | false |
custom_dod |
number | Optional | Custom DoD value as a percentage. Used when use_custom_dod is true |
100 |
calculate_reserve_from_dod |
boolean | Optional | Use custom DoD value to also calculate the battery reserve value. Note - using this also affects the timers | false |
display_custom_dod_stats |
boolean | Optional | Display the derived custom DoD (capacity and reserve) stats | true |
display_energy_today |
boolean | Optional | Display statistics for daily charge/discharge | true |
trickle_charge_filter |
boolean | Optional | Enable/disable trickle charge filter. If actual battery power < filter threshold, charge/discharge power will be displayed as zero and idle | false |
trickle_charge_filter_threshold |
number | Optional | If trickle charge filter is enabled, and the battery power is less than this value (in W), charge/discharge power will be displayed as zero and idle | 25 |
use_custom_sensors |
boolean | Optional | Enable to override the automatically derived sensor Entity IDs with user defined Entity IDs | false |
custom_soc |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_soc entity ID |
"" |
custom_battery_power |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_battery_power entity ID |
"" |
custom_soc_kwh |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_soc_kwh entity ID |
"" |
custom_discharge_power |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_discharge_power entity ID |
"" |
custom_charge_power |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_charge_power entity ID |
"" |
custom_battery_capacity_kwh |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_battery_capacity_kwh entity ID |
"" |
custom_battery_charge_energy_today_kwh |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_battery_charge_energy_today_kwh entity ID |
"" |
custom_battery_discharge_energy_today_kwh |
string | Optional | Override the default sensor.givtcp_INVERTOR_SERIAL_battery_discharge_energy_today_kwh entity ID |
"" |
custom_battery_power_reserve |
string | Optional | Override the default number.givtcp_INVERTOR_SERIAL_battery_power_reserve entity ID |
"" |
custom_battery_charge_rate |
string | Optional | Override the default number.givtcp_INVERTOR_SERIAL_battery_charge_rate entity ID |
"" |
custom_battery_discharge_rate |
string | Optional | Override the default number.givtcp_INVERTOR_SERIAL_battery_discharge_rate entity ID |
"" |
type: custom:givtcp-battery-card
entity: sensor.givtcp_abc123_invertor_serial_number
name: Battery
soc_threshold_very_high: 80
soc_threshold_high: 60
soc_threshold_medium: 40
soc_threshold_low: 20
soc_colour_input: rgb_picker
soc_threshold_very_high_colour:
- 0
- 69
- 23
soc_threshold_high_colour:
- 67
- 160
- 71
soc_threshold_medium_colour:
- 255
- 166
- 0
soc_threshold_low_colour:
- 219
- 68
- 55
soc_threshold_very_low_colour:
- 94
- 0
- 0
display_abs_power: false
display_type: 3
display_dp: 3
icon_status_idle: mdi:sleep
icon_status_charging: mdi:lightning-bolt
icon_status_discharging: mdi:home-battery
display_battery_rates: true
use_custom_dod: true
custom_dod: 95
calculate_reserve_from_dod: true
display_custom_dod_stats: true
display_energy_today: true
trickle_charge_filter: false
trickle_charge_filter_threshold: 25
use_custom_sensors: false
custom_soc: "sensor.custom_entity_id_for_soc"
custom_battery_power: ""
custom_soc_kwh: "sensor.custom_entity_id_for_soc_kwh"
custom_discharge_power: ""
custom_charge_power: ""
custom_battery_capacity_kwh: ""
custom_battery_charge_energy_today_kwh: ""
custom_battery_discharge_energy_today_kwh: ""
custom_battery_power_reserve: ""
custom_battery_charge_rate: ""
custom_battery_discharge_rate: ""soc_colour_input: theme_var
soc_threshold_very_high_colour: --success-color
soc_threshold_high_colour: --success-color
soc_threshold_medium_colour: --warn-color
soc_threshold_low_colour: --error-color
soc_threshold_very_low_colour: --error-colorOnce the invertor serial entity ID has been defined, the card will attempt to derive the rest of the
required sensors automatically. This default configuration should work for most systems, and users will generally
only need to define the sensor.givtcp_abc123_invertor_serial_number entity.
However, some systems may have non-standard entity IDs, or entity IDs that for one reason or another have been modified by GivTCP. In this case, the card will display an error message listing the sensor entity IDs that it cannot find.
In this case, it is possible to set the use_custom_sensors configuration value to true, and set custom entity IDs.
For example, the card automatically derives sensor.givtcp_INVERTOR_SERIAL_battery_power as the sensor to use for
battery power. The user's system, however, is using sensor.givtcp123_some_other_name_battery_power. In this case,
the card will output an error stating that sensor.givtcp_INVERTOR_SERIAL_battery_power cannot be found.
Simple enable the use_custom_sensors option, and set the custom_battery_power value to
sensor.givtcp123_some_other_name_battery_power
This can be done via the card editor GUI, or directly in the YAML configuration, e.g.
use_custom_sensors: true
custom_battery_power: "sensor.givtcp123_some_other_name_battery_power"Multiple invertors and batteries are currently not supported natively in a single card instance. A separate card for each invertor is recommended. However, a workaround is possible by creating "Combine the state of multiple sensors" Helpers in HA to combine sensor values into a single entity, then point the card configuration to these instead.
For example, a GivEnergy Gateway/AIO system with two batteries will have two separate entities for
givtcp_SERIAL_charge_power. A Helper entity can be created to combine these into a single entity:
sensor.givtcp_combined_charge_power:
sensor.givtcp2_SERIAL_charge_power
sensor.givtcp3_SERIAL_charge_powe
The use_custom_sensors config option can then be set to true, and custom_charge_power set to
sensor.givtcp_combined_charge_power. The card will now use sensor.givtcp_combined_charge_power instead of
the default sensor.givtcp_INVERTOR_SERIAL_charge_power to query the data.