Sydpower API reverse engineering
Concerned products: Fossibot power stations using BrightEMS application. Currently tested with F2400 and F3600 Pro.
node sydpower-run.js [USERNAME] [PASSWORD]
I'm not responsible for anything that this software can cause.
Be extra carefull with registers, possibles values are shown in sydpower-registers.js
For example, passing 0 to "whole machine unused time" will brick the device (I bricked one :D)
-
login to your account to get the needed authentication tokens
-
fetch your registered devices
-
connect to mqtt and get devices informations realtime
-
webserver is available to read status and trigger commands using routes:
-
view current status:
http://localhost:3000/devicesorhttp://localhost:3000/devices/:deviceId -
trigger command:
http://localhost:3000/devices/:deviceId/:commandorhttp://localhost:3000/devices/:deviceId/:command/:valueCommands and available values are listed in filesydpower-registers.jsExample:REGEnableACOutput
-
While waiting for a complete integration to be developped, you can run this nodejs application somewhere and fetch data with home assistant.
Use Home Assistant RESTful integration to do so.
A sample yaml is available: ha_rest.yaml
You can then have values and commands on lovelace
To call commands, just use in an action or automation one command, for example: rest_command.set_fossibot_xxxxx_enable_ac_output